We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

BACKGROUND: Although new-generation drug-eluting stents represent the standard of care among patients undergoing percutaneous coronary intervention, there remains debate about differences in efficacy and the risk of stent thrombosis between the Resolute zotarolimus-eluting stent (R-ZES) and the everolimus-eluting stent (EES). The aim of this study was to evaluate the safety and efficacy of the R-ZES compared with EES in patients undergoing percutaneous coronary intervention. METHODS AND RESULTS: A systematic literature search of electronic resources was performed using specific search terms until September 2014. Random-effects meta-analysis was performed comparing clinical outcomes between patients treated with R-ZES and EES up to maximum available follow-up. The primary efficacy end point was target-vessel revascularization. The primary safety end point was definite or probable stent thrombosis. Secondary safety end points were cardiac death and target-vessel myocardial infarction. Five trials were identified, including a total of 9899 patients. Compared with EES, R-ZES had similar risks of target-vessel revascularization (risk ratio [RR], 1.06; 95% confidence interval [CI], 0.90-1.24; P=0.50), definite or probable stent thrombosis (RR, 1.26; 95% CI, 0.86-1.85; P=0.24), cardiac death (RR, 1.01; 95% CI, 0.79-1.30; P=0.91), and target-vessel myocardial infarction (RR, 1.10; 95% CI, 0.89-1.36; P=0.39). Moreover, R-ZES and EES had similar risks of late definite or probable very late stent thrombosis (RR, 1.06; 95% CI, 0.53-2.11; P=0.87). No evidence of significant heterogeneity was observed across trials. CONCLUSIONS: R-ZES and EES provide similar safety and efficacy among patients undergoing percutaneous coronary intervention.

Original publication

DOI

10.1161/CIRCINTERVENTIONS.114.002223

Type

Journal article

Journal

Circ Cardiovasc Interv

Publication Date

04/2015

Volume

8

Keywords

everolimus-eluting stent, meta-analysis, randomized controlled trial, zotarolimus-eluting stent, Drug-Eluting Stents, Everolimus, Humans, Immunosuppressive Agents, Percutaneous Coronary Intervention, Postoperative Complications, Randomized Controlled Trials as Topic, Sirolimus, Survival Analysis, Thrombosis, Treatment Outcome