We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

BACKGROUND: The incidence of structural valve deterioration after bioprosthesis (BP) aortic valve replacement (AVR) established on the basis of reoperation may substantially underestimate the true incidence. The objective is to determine the rate, timing, correlates, and association between hemodynamic valve deterioration (HVD) and outcomes assessed by Doppler echocardiography after surgical BP AVR. METHODS: A total of 1387 patients (62.2% male, 70.5±7.8 years of age) who underwent BP AVR were included in this retrospective study. Baseline echocardiography was performed at a median time of 4.1 (1.3-6.5) months after AVR. All patients had an echocardiographic follow-up ≥2 years after AVR (926 at least 5 years and 385 at least 10 years). HVD was defined by Doppler assessment as a ≥10 mm Hg increase in mean gradient or worsening of transprosthetic regurgitation ≥1/3 class. HVD was classified according to the timing after AVR: "very early," during the first 2-years; "early," between 2 and 5 years; "midterm," between 5 and 10 years; and "long-term," >10 years. RESULTS: A total of 428 patients (30.9%) developed HVD. Among these patients, 52 (12.0%) were classified as "very early," 129 (30.1%) as "early," 158 (36.9%) as "midterm," and 89 (20.8%) as "long-term" HVD. Factors independently associated with HVD occurring within the first 5 years after AVR were diabetes mellitus ( P=0.01), active smoking ( P=0.01), renal insufficiency ( P=0.01), baseline postoperative mean gradient ≥15 mm Hg ( P=0.04) or transprosthetic regurgitation ≥mild ( P=0.04), and type of BP (stented versus stentless, P=0.003). Factors associated with HVD occurring after the fifth year after AVR were female sex ( P=0.03), warfarin use ( P=0.007), and BP type ( P<0.001). HVD was independently associated with mortality (hazard ratio, 2.18; 95% CI, 1.86-2.57; P<0.001). CONCLUSIONS: HVD as identified by Doppler echocardiography occurred in one third of patients and was associated with a 2.2-fold higher adjusted mortality. Diabetes mellitus and renal insufficiency were associated with early HVD, whereas female sex, warfarin use, and stented BPs (versus stentless) were associated with late HVD.

More information Original publication

DOI

10.1161/CIRCULATIONAHA.118.035150

Type

Journal article

Publication Date

2018-09-04T00:00:00+00:00

Volume

138

Pages

971 - 985

Total pages

14

Keywords

aortic valve replacement, bioprosthesis, diabetes, echocardiography, structural valve degeneration, Aged, Aortic Valve, Bioprosthesis, Echocardiography, Doppler, Female, Heart Valve Diseases, Heart Valve Prosthesis, Heart Valve Prosthesis Implantation, Hemodynamics, Humans, Male, Middle Aged, Prosthesis Design, Prosthesis Failure, Retrospective Studies, Risk Assessment, Risk Factors, Time Factors, Treatment Outcome